fix(code-runtime): reject a maxWallMs above Node's maximum timer delay
`config.maxWallMs` is only checked for positivity, and it is handed to `setTimeout`, which clamps any delay above 2^31-1 ms to 1 ms. A deployment configuring a 25-day wall ceiling therefore gets the opposite of what it asked for: every run times out on the first tick. The runtime now range-checks the field at load against MAX_TIMER_DELAY_MS from dsh-timeout and throws, so the misconfiguration fails loud where it is self-contained instead of silently inverting the budget. `computeMs` needs no matching bound: it is compared against measured event-loop utilization rather than fed to a timer. The test asserts both the rejection and that the boundary value itself loads.
This commit is contained in:
@@ -130,4 +130,4 @@ Deployments switching to `'code'` must update any native-only `toolOrder`. Assem
|
||||
|
||||
**Serialized-only sub-dispatch.** `Promise.all` gains no wall-clock parallelism yet, only fewer round-trips; models may over-expect. The instructions state it; lifting it is tied to the same concurrency-safety metadata the native parallel-dispatch TODO needs.
|
||||
|
||||
**Budget metering reads the event loop, not a flag.** Busy-time polling (`eventLoopUtilization()`) is coarser than an exact CPU meter — a budget expires up to one poll interval late — and its correctness claim ("a pending dispatch cannot pause it") is load-bearing against a hostile program. Both sides are unit-tested (hot loop with a pending decoy dispatch dies at `computeMs`; idle-on-slow-binding survives to `maxWallMs`), and the poll interval is an internal constant, not config — nothing a deployment could mis-tune into a bypass.
|
||||
**Budget metering reads the event loop, not a flag.** Busy-time polling (`eventLoopUtilization()`) is coarser than an exact CPU meter — a budget expires up to one poll interval late — and its correctness claim ("a pending dispatch cannot pause it") is load-bearing against a hostile program. Both sides are unit-tested (hot loop with a pending decoy dispatch dies at `computeMs`; idle-on-slow-binding survives to `maxWallMs`), and the poll interval is an internal constant, not config — nothing a deployment could mis-tune into a bypass. `maxWallMs` is config, and it reaches `setTimeout`, which clamps a delay above `MAX_TIMER_DELAY_MS` (2^31-1 ms) to 1 ms; a positivity check alone therefore accepts a 25-day ceiling that expires on the first tick and times out every run. The worker runtime range-checks the field at load for that reason. `computeMs` needs no upper bound because it is compared against measured utilization instead of being handed to a timer.
|
||||
|
||||
Reference in New Issue
Block a user