@@ -0,0 +1,6 @@
# Bilingual-pair consistency record (docs/i18n/README.md): the git blob hash of each
# side as of the last confirmed-consistent state. Both languages carry equal authority;
# after editing either side, bring the other along and re-record with:
# pnpm run verify-translation-pairing --write .agents/notes/implemented/bug-fix/2026-08-03-cli-signal-shutdown-escalation.md
2026-08-03-cli-signal-shutdown-escalation.md: 62abe7a8e6887345232bd5c429a9abc61a424b5d
2026-08-03-cli-signal-shutdown-escalation.zh.md: b8ccf94dc14a9363d8e373ebd13c4a89cd03e23c
@@ -0,0 +1,52 @@
# Agent Note: Bounded, escalating signal shutdown for Web and headless
Status: implemented
English | [中文](2026-08-03-cli-signal-shutdown-escalation.zh.md)
## Problem
The default telemetry mount added SIGINT/SIGTERM handlers to `dsh web` and `dsh -p` so process exit could drain the Cordis tree instead of dropping queued telemetry. Each handler used a one-way boolean latch and exited only after `ctx.fiber.dispose()` settled. Headless normal completion also awaited that disposal without a bound.
A user then reproduced `dsh -p` hanging immediately after the observation URL and ignoring repeated `Ctrl+C`; `DSH_TELEMETRY_DISABLED=1` removed the hang, while a standalone Node handler in the same Linux sandbox received SIGINT. This isolated the pending disposer to telemetry rather than terminal signal forwarding. OTel's `BatchLogRecordProcessor.shutdown()` awaits `exporter.forceFlush()` before the `exportTimeoutMillis`-bounded completion promise, and the OTLP exporter's `forceFlush()` waits directly on its in-flight HTTP Promise. A proxy/sandbox connection that never obtains a socket can therefore leave provider shutdown pending despite both configured SDK timeouts.
The latch then turned that telemetry defect into an unkillable CLI: normal completion was already awaiting the single-shot root disposal; the first SIGINT joined the same pending disposal and set the signal latch; later SIGINTs returned at the latch, so the process had no remaining escape. A signal received before normal completion had the same unbounded wait. Web used the same latch shape.
Telemetry's own timeouts cannot prove that the whole plugin tree settles. Any current or future disposer can wedge, and the process boundary must preserve both a graceful first attempt and a user-controlled way out.
## Decision
The fix has two ownership layers. The OTel backend adds `shutdownTimeoutMillis` (default and shipped value: three seconds) around the SDK provider's complete shutdown Promise. Crossing it rejects into the telemetry coordinator's existing contained-failure path, allowing the Cordis tree to finish disposal; pending records may be lost because OTel exposes no cancellation for the transport Promise.
Web and headless share `createProcessShutdown`, one process-level controller around root disposal:
- Normal shutdown calls coalesce onto one disposal and retain the first requested exit code; they never escalate one another.
- The first signal starts the same graceful disposal and a referenced five-second exit backstop. Disposal success or failure exits once; neither can cancel the process exit.
- A signal received while shutdown is pending forces immediate exit with that signal path's code. This includes the first `Ctrl+C` after headless normal completion has already entered disposal, and a second signal after a signal initiated the drain.
- The five-second bound is a process-safety invariant, not a deployment tunable. It matches the existing TUI root-disposal allowance and is long enough for the telemetry deployment's ordinary drain ceiling.
Headless preserves exit 0 for a completed turn, exit 1 for another turn-end reason or API business error, 130 for SIGINT, and 143 for SIGTERM. Web preserves its existing SIGTERM exit 0 and SIGINT exit 130 behavior.
This supersedes the [telemetry deployment Note's](../feature/2026-07-31-web-telemetry-default-mount.md) assumption that SDK exporter/processor timeouts bound complete provider shutdown, and its earlier decision to defer a process-level backstop. The backend owns its export loss/latency policy and closes the known SDK `forceFlush()` gap; the launcher owns the outer guarantee that no plugin can trap the process indefinitely.
## Alternatives considered
**Bound only the telemetry backend's `shutdown()`.** Insufficient because it protects the known OTel wait but cannot protect the launcher from another plugin's disposer.
**Restore Node's default immediate signal exit.** Rejected because a healthy first signal should still flush telemetry and release other resources. Immediate exit is the explicit escalation path, not the default.
**Add only the five-second timeout.** Rejected because a user pressing `Ctrl+C` again is asking to stop waiting now. Swallowing that intent for the rest of the grace period recreates the reported behavior at a shorter duration.
## Consequences
A healthy exit still disposes the complete Cordis tree. The known telemetry wait releases after at most three seconds; any other wedged exit lasts at most five seconds without further input, and a repeated signal ends it immediately. Forced or deadline-bounded exit can interrupt telemetry export or remaining cleanup, which is intentional only after the graceful contract has failed or the user has explicitly escalated.
The controller is launcher infrastructure rather than a Cordis plugin: it makes no claim that disposal completed, and it does not weaken the lifecycle rule that ordinary disposers must reach quiescence.
## Testing
`apps/cli/tests/process-shutdown.spec.ts` pins resolved and rejected disposal, the five-second backstop, normal-call coalescing, a signal interrupting normal disposal, and second-signal escalation.
`apps/cli/tests/headless-shutdown.e2e.ts` boots the real shipped Web/headless Loader tree in a PTY with a test-only plugin whose disposer announces entry and never settles. The test sends SIGINT after the observation URL, waits for proof that disposal started, sends SIGINT again, and requires exit 130. The source/artifact launch resolver keeps the same regression on both execution planes. This PTY case covers the user-visible process state; no model-output snapshot changes.
`packages/telemetry/session-telemetry-otel/tests/otel.spec.ts` holds a real OTLP request open after timer export begins and pins that Cordis disposal returns at `shutdownTimeoutMillis`, despite the SDK's `forceFlush()` remaining pending. The collector is then released so the still-observed provider Promise settles cleanly.
@@ -0,0 +1,52 @@
# Agent NoteWeb 与 headless 的有界信号关闭和重复信号强制退出
状态:已实现
[English](2026-08-03-cli-signal-shutdown-escalation.md) | 中文
## 问题
默认挂载遥测后,`dsh web``dsh -p` 新增了 SIGINT/SIGTERM 处理器,使进程退出时可以排空 Cordis 插件树,而不是丢弃排队中的遥测数据。每个处理器都使用单向布尔闩锁(latch),并且只有在 `ctx.fiber.dispose()` 结算后才退出。headless 正常完成时同样会无界等待整棵树执行 dispose(资源释放)。
随后有用户复现,`dsh -p` 在打印观察 URL 后立即卡死,重复按 `Ctrl+C` 也没有反应;设置 `DSH_TELEMETRY_DISABLED=1` 后不再卡死,而同一 Linux 沙箱中的独立 Node 信号处理器能够收到 SIGINT。这将待结算的 disposer 定位到遥测,而非终端信号转发。OTel 的 `BatchLogRecordProcessor.shutdown()` 会先等待 `exporter.forceFlush()`,再进入受 `exportTimeoutMillis` 限制的完成 promiseOTLP 导出器的 `forceFlush()` 则直接等待正在进行的 HTTP Promise。因此,代理/沙箱连接始终无法取得 socket 时,即使已经配置两项 SDK 超时,也会让提供方关闭一直待结算。
闩锁随后把这个遥测缺陷变成无法终止的 CLI(命令行界面):正常完成流程已经在等待单次根级 dispose;第一次 SIGINT 会加入同一个待结算的 dispose,并设置信号闩锁;后续 SIGINT 在闩锁处直接返回,因此进程再无退出途径。正常完成之前收到信号时,同样会陷入无界等待。Web 使用的闩锁结构与此相同。
遥测自身的超时无法证明整棵插件树都能结算。任何当前或未来的 disposer 都可能卡死;进程边界既要保留第一次优雅关闭的机会,也必须给用户留下强制退出的途径。
## 决策
修复分为两层归属。OTel 后端围绕 SDK 提供方的完整关闭 Promise 增加 `shutdownTimeoutMillis`(默认值和交付值均为 3 秒)。超过该截止时间时会 reject,并进入遥测协调器现有的失败隔离路径,使 Cordis 插件树能够完成 dispose;由于 OTel 未公开取消传输 Promise 的能力,待处理记录可能丢失。
Web 与 headless 共用 `createProcessShutdown`,它是围绕根级 dispose 建立的进程级控制器:
- 多次正常关闭调用会汇合到同一次 dispose,并保留首次请求的退出码;这些调用不会相互触发强制退出。
- 第一个信号会启动同一次优雅 dispose,并设置一个带引用的 5 秒退出兜底。dispose 无论成功或失败都会触发且仅触发一次退出;任何一种结果都无法取消进程退出。
- 关闭待结算期间收到信号时,会立即按该信号路径的退出码强制退出。这既包括 headless 正常完成已经进入 dispose 后收到的第一次 `Ctrl+C`,也包括由信号启动排空后收到的第二个信号。
- 5 秒上限是进程安全不变式,而不是部署调节项。它与现有 TUI 根级 dispose 的等待上限一致,也足以覆盖遥测部署的常规排空时限。
headless 对完成的轮次仍以 0 退出,对其他轮次结束原因或 API 业务错误仍以 1 退出,对 SIGINT 以 130 退出,对 SIGTERM 以 143 退出。Web 保留现有行为:SIGTERM 以 0 退出,SIGINT 以 130 退出。
这项决策取代了[遥测部署 Agent Note](../feature/2026-07-31-web-telemetry-default-mount.md) 中 SDK 导出器/处理器超时能够限制提供方完整关闭流程的假设,也取代了其中暂缓进程级退出兜底的决定。后端负责导出数据丢失与延迟策略,并封住已知的 SDK `forceFlush()` 缺口;启动器负责最外层保证,确保任何插件都无法无限期困住进程。
## 考虑过的替代方案
**只限制遥测后端的 `shutdown()`。** 仍不充分:它能保护已知的 OTel 等待,但无法保护启动器免受其他插件 disposer 的影响。
**恢复 Node 默认的信号即时退出。** 不予采纳:收到第一个信号时,健康流程仍应刷新遥测数据并释放其他资源。即时退出是显式的强制退出路径,而非默认行为。
**只增加 5 秒超时。** 不予采纳:用户再次按下 `Ctrl+C`,就是要求立即停止等待。若在剩余宽限期内继续吞掉这一意图,只是缩短了报告中故障的持续时间,并未解决问题。
## 后果
健康的退出流程仍会对整棵 Cordis 插件树执行 dispose。已知的遥测等待最多会在 3 秒后解除;其他退出流程卡死时,如无进一步输入,最多等待 5 秒,再次收到信号则立即结束进程。强制退出或受截止时间限制的退出可能中断遥测导出或尚未完成的清理工作;只有优雅关闭契约已经失败,或用户明确要求强制退出时,才会有意接受这一结果。
该控制器属于启动器基础设施,而不是 Cordis 插件:它不会声称 dispose 已经完成,也不会削弱普通 disposer 必须达到完全停稳状态的生命周期规则。
## 测试
`apps/cli/tests/process-shutdown.spec.ts` 固定了 dispose 成功与失败、5 秒退出兜底、正常调用汇合、信号中断正常 dispose,以及第二次信号强制退出的行为。
`apps/cli/tests/headless-shutdown.e2e.ts` 在 PTY 中启动真实交付的 Web/headless Loader 插件树,并挂载一个仅用于测试的插件;该插件的 disposer 会声明已经进入清理流程,但永不结算。测试在观察地址出现后发送 SIGINT,等待 dispose 已启动的证据,再次发送 SIGINT,并要求进程以 130 退出。源码/产物启动解析器使两个执行平面都覆盖同一项回归。该 PTY 用例覆盖用户可见的进程状态;模型输出快照没有变化。
`packages/telemetry/session-telemetry-otel/tests/otel.spec.ts` 在定时器导出开始后保持一条真实 OTLP 请求打开,并固定以下行为:即使 SDK 的 `forceFlush()` 仍待结算,Cordis dispose 也会在 `shutdownTimeoutMillis` 到期时返回。随后测试释放 collector,使仍受观察的提供方 Promise 干净结算。